When Brain Tumors Recur: How Taipei Veterans General Hospital Uses BNCT

From BPA-PET case selection to individualised dose planning, blood boron measurement and neutron monitoring - inside Taipei Veterans General Hospital's clinical experience with BNCT for recurrent brain tumors.

Listen
Audio Narration
00:00 / 00:00
SNQ – Symbol of National Quality

SNQ is built on evidence-based standards, setting trusted quality and safety benchmarks for healthcare, biomedical, health, and animal care services and products.

  • 9F, No. 508, Sec. 7, Zhongxiao E. Rd., Nangang Dist., Taipei City, Taiwan
  • +886 2 2655 7888
  • snq@snq.com.tw

About

  • Vision & Mission
  • Review Committee
  • Certification Schedule

Application

  • Medical Service
  • Biomedical Product
  • Health Product
  • Animal Care & Products

SNQ Certified

  • Certified Services & Products
  • Certified Organizations
  • Quality Award Winners

International Certification

  • ICHOM PROMs
  • NSF Certification

Quality Insights

  • Apply for Certification →
Organized by|Research Center for Biotechnology and Medicine PolicyOperated by|Broadway International Standards Co., Ltd.© 2026 Broadway International Standards Co., Ltd. All rights reserved.Privacy Policy
SNQ – Symbol of National Quality
繁中
/
EN
Key Takeaways
01
Selection: T/N of 2.5 or above, with fitness and feasibility
  • ·BPA-PET assesses the tumour-to-normal tissue uptake ratio
  • ·A Karnofsky Performance Status (KPS) below 60, organ function or laboratory values out of range, and uncontrolled infection are grounds for ineligibility
  • ·Irradiation geometry, dose feasibility and other standard options are weighed at the same time
02
Planning: dose simulation, boron measurement and neutron monitoring
  • ·Individual treatment plans built with TH-BNCTplan
  • ·Blood boron measured by ICP-AES, with BPA concentrations recorded
  • ·Real-time neutron monitoring, delivery and plan review are all included in quality control
03
34 cases: ORR 50%, DCR 85.3%
  • ·Patients enrolled were critically ill and had exhausted their treatment options
  • ·Complete response 17.6%, partial response 32.4%, stable disease 35.3%
  • ·Published in Biology in 2021

Re-irradiating a recurrent malignant brain tumor is constrained by the radiation dose the surrounding normal brain can tolerate. Boron neutron capture therapy (BNCT) exploits the tumor selectivity of boron-containing drugs to offer another option when conventional treatment options are limited; delivering it clinically involves assessing drug uptake, selecting patients and planning dose individually.

In a published series of 34 malignant brain tumor cases, the team recorded an objective response rate (ORR) of 50% and a disease control rate (DCR) of 85.3%. These were patients whose treatment options had been exhausted, making patient selection, dose planning and treatment monitoring central to this clinical experience.

The Department of Heavy Particles and Radiation Oncology at Taipei Veterans General Hospital has been developing BNCT for brain tumors since 2017. Department director Yu-Ming Liu, attending physician Yi-Wei Chen and a cross-disciplinary team work with the neutron irradiation facility at National Tsing Hua University, and have accumulated 322 brain tumor treatment sessions.

Beyond the BPA-PET uptake ratio: patient condition and irradiation feasibility

The team uses BPA-PET to assess the tumor-to-normal tissue uptake ratio (T/N), setting T/N of 2.5 or above as a selection criterion, and weighs it together with KPS, organ function, laboratory results and infection control.

The main reasons for declining a case are a T/N below 2.5, a KPS below 60, irradiation geometry or dose that is not feasible, and organ function or laboratory values outside the required range. Whether standard treatment is still available, whether the lesion suits BNCT, and whether infection is controlled are also part of the assessment.

Each case is discussed jointly by heavy particle and radiation oncology, neurosurgery, nuclear medicine, radiology, nursing and pharmacy, with a dedicated multidisciplinary meeting for each case to reach a treatment decision. Meeting the uptake threshold is not the end of it; the patient's condition and the practicality of delivering treatment still have to be confirmed.

Individualised dose simulation, blood boron levels and irradiation quality control

Treatment plans are simulated with TH-BNCTplan. On the pharmaceutical side, L-BPA injection is prepared to GMP specifications, and ICP-AES equipment measures boron concentration, recording blood boron levels through the course of treatment.

Irradiation is paired with real-time neutron monitoring, bringing the treatment plan, concentration measurement, delivery and record review into quality control. Taipei Veterans General Hospital handles pre-treatment assessment and follow-up care; the Nuclear Science and Technology Development Center at National Tsing Hua University provides the neutron irradiation facility.

The workflow brings together the expertise needed for the boron drug, the dose calculation and the neutron irradiation, and keeps records at each stage for treatment review and later analysis.

Thirty-four emergency and compassionate use cases

The study the team published in Biology in 2021 analysed 34 patients with malignant brain tumors treated with BNCT on an emergency or compassionate use basis.

Complete response 17.6%, partial response 32.4%, stable disease 35.3% - an ORR of 50% and a DCR of 85.3%.
Supporting Literature (https://www.mdpi.com/2079-7737/10/4/334?utm_source=chatgpt.com)

The study offers clinical data on BNCT in patients who had exhausted their options, and the results should be read with that context in mind. The 34 patients in the study and the 322 brain tumor treatment sessions the team has accumulated are different counts; treatment records and subsequent responses continue to be entered into the BNCT record system for quality management and research.

The 2nd Asia-Pacific Conference on Healthcare Quality
The 2nd Asia-Pacific Conference on Healthcare Quality

Saturday, December 6, 2025, 09:30–12:30 · International Linkage Pavilion, 4F, Nangang Exhibition Center, Hall 1

Organized by the Institute for Biotechnology and Medicine Industry (IBMI)
Sign up now→
Related Certifications03
2025 · Taipei Veterans General Hospital · Hospital
BNCT for Malignant Brain Tumors
2025 · Chang Gung Medical Foundation Linkou Chang Gung Memorial Hospital · Hospital
Precision Medicine for Brain Tumors
Taipei Medical University-Shuang Ho Hospital, Ministry of Health and Welfare · Hospital
Brain Tumors & AVMs
Related ReadingRELATED
90-Day Mortality Risk Down 31% for High-Risk Patients: How a Tri-Service General Hospital Team Used AI Alerts to Save Lives
Best Practices

90-Day Mortality Risk Down 31% for High-Risk Patients: How a Tri-Service General Hospital Team Used AI Alerts to Save Lives

2026/09/23
From Open Surgery to Minimally Invasive Repair: Taipei Tzu Chi’s Achilles Tendon Technique
Best Practices

From Open Surgery to Minimally Invasive Repair: Taipei Tzu Chi’s Achilles Tendon Technique

2026/09/23
From AI Imaging to Precision Cancer Care: Clinical Innovation at the University of Tokyo Hospital
Best Practices · Asia-Pacific Healthcare Quality Forum

From AI Imaging to Precision Cancer Care: Clinical Innovation at the University of Tokyo Hospital

2026/09/23